Welcome to the DS150i manual, your guide to understanding and utilizing the DS150i passive-infrared detector for request-to-exit applications․ This manual provides essential information for installation, operation, and troubleshooting, ensuring optimal performance and compliance with safety standards․
1․1 Overview of the DS150i Detector
The DS150i is a passive-infrared detector designed for request-to-exit (REX) applications, offering reliable motion detection for access control systems․ It features UL 294 listing for access control devices and ULC-S319 compliance for Canada․ Available in light gray (DS150i) and black (DS151i), it provides flexible mounting options, adjustable settings, and selectable operational modes․ Its compact design and wrap-around coverage pattern make it suitable for single or double door installations, ensuring seamless integration into various security environments while maintaining aesthetic appeal․
1․2 Importance of the Manual for Installation and Operation
This manual is crucial for ensuring the correct installation, configuration, and operation of the DS150i detector․ It provides detailed guidance on safety precautions, compliance with standards, and troubleshooting common issues․ By following the manual, users can optimize the detector’s performance, ensure reliability, and maintain compliance with regulatory requirements․ Proper installation and operation are essential for the detector to function effectively in request-to-exit applications, making this manual an indispensable resource for installers and operators․
Key Features of the DS150i Detector
The DS150i detector features passive-infrared technology, request-to-exit functionality, UL 294 compliance, and adjustable settings like relay trigger modes and latch times for tailored performance in access control systems․
2․1 Passive-Infrared Technology
The DS150i employs passive-infrared (PIR) technology to detect motion by sensing infrared radiation changes within its coverage area․ This reliable method ensures accurate detection while minimizing false alarms․ PIR technology operates without emitting energy, making it energy-efficient and discreet․ The detector’s advanced sensor design provides consistent performance under various environmental conditions, ensuring it functions effectively for request-to-exit applications․ This technology is a cornerstone of the DS150i’s ability to deliver accurate and reliable motion detection in access control systems․ Its efficiency and accuracy make it a preferred choice for secure environments․
2․2 Request-to-Exit (REX) Applications
The DS150i is specifically designed for request-to-exit (REX) applications, ensuring seamless integration with access control systems․ It detects motion within its coverage area, signaling the system to unlock doors or grant access․ This feature enhances security by preventing unauthorized entry while allowing legitimate exit requests; The detector’s reliability in REX scenarios makes it ideal for commercial and industrial settings, providing efficient and secure access management solutions․
2․4 UL Listing and Compliance
The DS150i is UL Listed under the UL 294 standard for access control devices, ensuring compliance with safety and performance requirements․ Additionally, it meets ULC-S319 standards for Canada, making it suitable for installations across North America․ This certification guarantees the detector’s reliability and adherence to industry regulations, providing users with a trusted solution for their access control needs․ Compliance with these standards also simplifies the installation process and ensures compatibility with other certified devices․
2․5 Design and Color Variants (DS150i and DS151i)
The DS150i series includes two models: the DS150i in light gray and the DS151i in black, offering aesthetic flexibility for various installations․ Both detectors share identical functionality but differ in color to suit different environments․ Their sleek, compact designs ensure discreet installation while maintaining performance․ The DS150i and DS151i are wall or ceiling mountable, with optional trim plates for enhanced appearance․ Despite the color difference, both models deliver the same reliable motion detection and operational features, ensuring consistent performance across applications․ Their design ensures seamless integration into any setting, making them versatile for diverse security needs․
Technical Specifications
The DS150i detector offers a coverage area with adjustable settings, including relay trigger modes and fail-safe/secure options․ It supports wall or ceiling mounting for versatile installation․
3․1 Coverage Area and Detection Range
The DS150i detector provides a wide coverage area, ensuring reliable motion detection for request-to-exit applications․ Its detection range is optimized for single or double door setups, offering consistent performance in various environments․ The detector’s wrap-around coverage pattern enhances its ability to monitor spaces effectively, making it suitable for both wall and ceiling installations․ This feature ensures that the device can accurately detect movement within its specified range, providing a robust solution for access control systems․
3․2 Mounting Options (Wall or Ceiling)
The DS150i detector offers flexible mounting options, allowing installation on either a wall or ceiling, depending on the specific application requirements․ Its compact design and internal vertical pointability ensure optimal coverage regardless of the mounting position․ The detector is suitable for single or double door setups, providing versatile installation options to meet various environmental needs․ This adaptability ensures reliable performance in diverse access control scenarios, making it a practical solution for both new and existing security systems․ Proper mounting ensures accurate detection and functionality․
3․3 Adjustable Settings (Relay Trigger, Fail Safe/Fail Secure Modes)
The DS150i detector features adjustable settings to customize its operation․ Selectable relay trigger modes allow for tailored responses to motion detection, ensuring compatibility with various access control systems․ Additionally, the detector offers fail-safe and fail-secure operational modes, providing flexibility in security configurations․ These modes ensure the system behaves predictably during power failures or system malfunctions, enhancing overall reliability․ The adjustable latch time, ranging from 0․5 to 64 seconds, further allows for customized control over door release duration, accommodating different access control needs and ensuring seamless integration into existing security setups․
3․4 Latch Time Adjustability (0․5 to 64 Seconds)
The DS150i detector offers adjustable latch time settings, allowing users to customize the duration the relay remains active after detecting motion․ Ranging from 0․5 to 64 seconds, this feature ensures flexibility in tailoring the device to specific access control requirements․ Whether for quick door releases or extended access periods, the adjustable latch time accommodates various security needs, enhancing system functionality and user convenience․ This feature is easily configurable during installation, providing a seamless integration into existing security setups while maintaining reliability and performance․
Installation Instructions
This section provides a step-by-step guide for installing the DS150i detector, including pre-installation checks, mounting options, and connecting to the control system․ It also covers optional trim plate installation and initial testing to ensure proper functionality and alignment with system requirements․
4․1 Pre-Installation Checklist
Before installing the DS150i detector, ensure you have the necessary tools and materials․ Verify the detector’s compatibility with your access control system and ensure the power supply meets requirements․ Check the coverage area to determine the optimal mounting location․ Review the UL 294 standard compliance and ULC-S319 listing for Canada․ Ensure all mounting hardware and optional trim plates (TP160 or TP161) are available․ Familiarize yourself with the installation manual and safety guidelines to avoid damage or improper setup․
4․2 Mounting the Detector
Mount the DS150i detector on a wall or ceiling, ensuring it is level and securely fastened․ For wall mounting, position the detector at a height of 7-8 feet from the floor․ For ceiling mounting, ensure the detector is at least 12 inches away from any obstructions․ Use the provided mounting hardware to ensure stability․ Align the detector to cover the desired area, considering the wrap-around coverage pattern․ If aesthetics are a priority, install the optional trim plate (TP160 or TP161) for a sleek appearance․ Refer to Figure 1 for detailed mounting instructions․
4․3 Connecting the Detector to the Control System
Connect the DS150i detector to your access control system using the appropriate wiring․ Ensure all connections are secure and match the terminal designations (IN, OUT, COM)․ Use 18-22 AWG wires for reliable signal transmission․ Verify compatibility with your control unit and power supply․ Follow the wiring diagram in the manual to avoid errors․ After connecting, test the system to ensure proper communication․ Refer to the control system’s manual for specific integration requirements․ Proper wiring ensures reliable operation and compliance with UL and ULC standards․
4․4 Optional Trim Plate Installation
For a sleek appearance, install the optional trim plate (TP160 or TP161) after mounting the detector․ Align the trim plate with the detector’s housing and secure it using the provided screws․ Ensure the plate is flush and evenly fitted․ Refer to the manual for specific alignment instructions․ The trim plate enhances aesthetics without affecting functionality․ Choose between light gray (TP160) or black (TP161) to match your detector’s color․ Proper installation ensures a professional finish and maintains the detector’s performance․ Always follow the manufacturer’s guidelines for trim plate installation․
4․5 Initial Testing and Setup
After installation, perform initial testing to ensure proper functionality․ Power up the detector and verify motion detection within its coverage area․ Test signal transmission to the control system, confirming relay activation․ Adjust settings like latch time (0․5 to 64 seconds) and relay trigger modes (fail safe/fail secure) as needed․ Ensure the detector aligns with system requirements and operational expectations․ Document all configurations for future reference․ This step ensures reliable performance and proper integration with access control systems, meeting security and safety standards effectively․ Proper setup guarantees optimal detection and system response․
Certifications and Compliance
The DS150i meets UL 294 and ULC-S319 standards, ensuring compliance with access control regulations․ It is designed for reliable performance in security systems, adhering to strict safety and industry norms․
5․1 UL 294 Standard for Access Control Devices
The DS150i complies with the UL 294 standard, which outlines specific requirements for access control devices․ This certification ensures the detector meets rigorous testing criteria for reliability, safety, and performance․ Designed for request-to-exit applications, the DS150i operates in fail-safe or fail-secure modes, aligning with UL 294 guidelines․ This compliance guarantees the device functions effectively in securing access points while adhering to U․S․ safety standards, making it a trusted solution for access control systems․
5․2 ULC-S319 Listing for Canada
The DS150i is listed under the ULC-S319 standard for Canada, ensuring compliance with Canadian safety regulations․ This certification verifies the detector’s reliability for access control applications in Canadian markets․ The ULC-S319 listing mandates that the DS150i must be connected to compatible ULC-listed devices, such as control units and locks, to maintain compliance․ This ensures the detector functions safely and effectively in request-to-exit scenarios, adhering to Canada’s stringent safety standards and providing users with a trusted security solution․
Operation and Functionality
The DS150i operates using passive-infrared technology to detect motion and signal access control systems․ It offers selectable relay modes and fail-safe/fail-secure functionality for reliable performance․
6․1 Motion Detection and Signal Transmission
The DS150i employs passive-infrared (PIR) technology to detect motion within its coverage area․ Upon detecting movement, it transmits a signal to the connected access control system or door control device․ This signal triggers the appropriate response, such as unlocking doors or activating alarms․ The detector’s wrap-around coverage pattern ensures comprehensive monitoring, while internal vertical pointability allows for precise adjustments to detection zones, enhancing accuracy and reducing false alarms․ This reliable functionality ensures smooth operation in various access control scenarios․
6․2 Selectable Relay Trigger Modes
The DS150i offers selectable relay trigger modes, providing flexibility in access control systems․ These modes allow customization of the detector’s response to motion detection, ensuring compatibility with various system requirements․ The fail-safe mode ensures doors unlock during power failures, while fail-secure mode keeps doors locked․ Adjustable latch times, ranging from 0․5 to 64 seconds, further enhance functionality․ This adaptability makes the DS150i suitable for diverse applications, from single to double-door configurations, while maintaining reliable performance and security; Proper configuration ensures seamless integration with access control systems․
6․3 Fail Safe and Fail Secure Operational Modes
The DS150i features fail-safe and fail-secure modes, ensuring reliable operation during power failures or system issues․ Fail-safe mode unlocks doors, prioritizing safety, while fail-secure mode maintains security by keeping doors locked․ These modes are critical for access control systems, allowing customization based on specific security requirements․ Proper configuration of these settings is essential for optimal functionality and compliance with safety standards․ This flexibility ensures the DS150i adapts to various applications, providing consistent performance and security․ Regular checks are recommended to maintain desired operational settings․
Troubleshooting Common Issues
Identify and resolve common issues with the DS150i, such as no power, detection problems, or false alarms, by referencing the manual for detailed solutions and adjustments․
7․1 No Power or Detection Issues
If the DS150i detector experiences no power or detection issues, first check the power supply connections and ensure they are secure․ Verify that the detector is properly mounted and aligned․ Clean the lens to remove any obstructions․ If issues persist, refer to the troubleshooting section for reset procedures or contact technical support for further assistance․ Always ensure the device is installed according to the manual’s specifications to maintain optimal functionality․
7․2 False Alarms or Unreliable Performance
False alarms or unreliable performance with the DS150i detector can often be resolved by checking the sensor’s alignment and ensuring it is free from obstructions․ Verify that the detector is properly mounted and adjusted according to the installation manual․ Clean the lens regularly to prevent interference from dust or debris․ If issues persist, adjust the sensitivity settings or refer to the troubleshooting guide for additional solutions․ Ensure all connections are secure and consult technical support if problems continue for further assistance․
Maintenance and Care
Regular maintenance ensures optimal performance of the DS150i detector․ Clean the lens with a soft cloth to prevent dust buildup․ Check alignment and secure connections․ Perform periodic tests as outlined in the manual to verify functionality and address potential issues promptly․
8․1 Cleaning the Detector
Regular cleaning is essential to maintain the DS150i detector’s performance․ Use a soft, dry cloth to wipe the lens and housing, removing dirt or debris․ For stubborn smudges, dampen the cloth with mild soap solution, but avoid harsh chemicals or abrasive materials․ Ensure the detector is powered off during cleaning to prevent damage․ Avoid touching the lens, as fingerprints can reduce accuracy․ Cleaning ensures reliable motion detection and extends the device’s lifespan․ Perform this maintenance periodically, especially in environments prone to dust or moisture․
8․2 Regular Performance Checks
Regular performance checks ensure the DS150i detector operates reliably․ Test the detection range by moving through the coverage area to confirm consistent motion sensing․ Verify relay trigger modes and fail safe/fail secure settings function as configured․ Inspect the lens for obstructions and ensure proper alignment․ Perform these checks every 1-3 months, or more frequently in high-traffic or harsh environments․ Address any issues promptly to maintain optimal performance and security․ This routine helps identify potential problems before they escalate, ensuring uninterrupted operation of the detector․ Regular checks are crucial for long-term reliability and accurate motion detection․
Integration with Access Control Systems
The DS150i detector seamlessly integrates with access control systems, ensuring reliable motion detection and signal transmission․ Compatible with UL-listed control units, it supports secure and efficient door control operations․
9․1 Compatible Control Units and Power Supplies
The DS150i detector is designed to work seamlessly with UL-listed control units and power supplies, ensuring compliance with safety standards․ For C-UL listed installations, it must be connected to ULC-S319 listed devices, such as compatible control units, power supplies, and locks․ Proper pairing ensures reliable operation and adherence to regulatory requirements․ Always verify compatibility before installation to maintain system performance and safety; Using non-listed devices may result in non-compliance with local regulations and safety standards․
9․2 Signal Output and wiring Requirements
The DS150i detector provides a relay output for signal transmission to access control systems or door control devices․ Wiring must comply with local electrical codes and the device’s UL 294 and ULC-S319 listings․ Use appropriately rated wires for power and signal connections, ensuring secure wiring to prevent false alarms․ The detector’s relay trigger mode can be configured to meet specific system requirements․ Always follow the manual’s wiring diagrams and recommendations to ensure proper installation and reliable operation of the request-to-exit functionality․
Accessories and Optional Equipment
Enhance the functionality and aesthetics of your DS150i detector with optional accessories like trim plates (TP160 or TP161) for a sleek installation and additional mounting hardware for flexibility․
10․1 Trim Plates (TP160 or TP161)
The TP160 and TP161 trim plates are designed to complement the DS150i and DS151i detectors, offering a sleek and professional appearance․ These optional accessories can be installed to cover any wiring or mounting hardware, ensuring a clean finish․ The TP160 is compatible with the DS150i, while the TP161 is designed for the DS151i, maintaining aesthetic consistency with their respective color schemes․ Refer to the installation manual for detailed mounting instructions with these trim plates to achieve a seamless integration with your access control system․
10․2 Additional Mounting Hardware
Enhance the installation flexibility of your DS150i detector with optional mounting hardware․ These accessories provide robust solutions for various setups, ensuring secure and precise placement․ Whether wall or ceiling mounting, the additional hardware ensures stability and alignment, optimizing detection performance․ Designed to meet diverse installation needs, these components maintain the detector’s reliability and functionality while blending seamlessly with its design․ Consult the manual for compatibility and installation guidance to maximize the effectiveness of your access control system․
Warranty and Support
The DS150i is backed by a comprehensive manufacturer warranty, ensuring coverage for defects in materials and workmanship․ Bosch provides dedicated technical support, including online resources, manuals, and expert assistance, to address any queries or issues․ This commitment to quality and customer satisfaction ensures long-term reliability and performance of the DS150i detector in access control systems․
11․1 Manufacturer Warranty Details
The DS150i detector is covered by a manufacturer warranty that ensures protection against defects in materials and workmanship․ The warranty period and terms are outlined in the manual, providing assurance of product reliability․ Bosch stands behind the quality of the DS150i, offering repairs or replacements for defective units within the specified warranty duration․ For specific details, including coverage limitations and conditions, refer to the official Bosch documentation or contact their customer support team․ Proper installation and maintenance are essential to uphold warranty validity․
11․2 Technical Support Resources
Bosch provides comprehensive technical support resources for the DS150i detector, including detailed manuals, guides, and specifications․ Users can access official documentation, such as installation manuals and technical bulletins, through the Bosch website or authorized distributors․ Additionally, customer support teams are available to address inquiries and provide assistance․ Online forums and troubleshooting guides further enhance support options, ensuring optimal performance and resolving issues efficiently․ These resources are designed to help users maximize the functionality of their DS150i detector․
The DS150i manual provides a comprehensive guide for installing, operating, and maintaining the detector, ensuring reliable performance in request-to-exit applications and compliance with safety standards․ Proper setup and adherence to guidelines are crucial for optimal functionality and longevity, making the DS150i an excellent choice for access control systems․ Follow the manual carefully to maximize its capabilities and ensure seamless operation․
12․1 Summary of Key Features and Benefits
The DS150i detector offers advanced passive-infrared technology for reliable motion detection in request-to-exit applications․ Its UL 294 and ULC-S319 listings ensure compliance with safety standards․ The device features selectable relay modes, fail-safe/fail-secure operation, and adjustable latch times․ Available in two designs (DS150i and DS151i), it provides flexibility for various installations․ Wall or ceiling mounting options and internal pointability enhance coverage․ The detector’s wrap-around pattern and minimal interference design ensure accurate detection․ These features make it a robust, versatile, and cost-effective solution for access control systems․
12․2 Importance of Proper Installation and Maintenance
Proper installation and maintenance of the DS150i detector are crucial for ensuring reliable performance and safety․ Correct mounting, wiring, and setup guarantee accurate motion detection and compliance with safety standards․ Regular cleaning and performance checks prevent issues like false alarms or reduced sensitivity․ Adhering to manufacturer guidelines ensures optimal functionality and extends the life of the device․ Proper maintenance also helps maintain system security and reduces the risk of operational failures, ensuring the detector operates as intended in various environments and conditions․